What are you talking about? Of course, energy that isn't used in the household is pushed back to the grid.
No, that’s not how it works in the general case. There are ways to setup a house to back power but it’s more complicated than just plugging it in.
Without proper safeties in place back flowing power to the grid becomes extremely dangerous for line technicians
So what you're saying is that the general case is that it feeds back into the grid unless there are additional measures taken? But at the same time, it's not the general case? Huh?
Which is why, where I live, you have to register your devices with the utility company.
On loss of power these inverters cut off within 20 ms or so. These are grid-tied, not insular (though with hacked firmware some of the models can be made insular-capable).
20ms are exactly 1/50th of a second i.e. our grid frequency I think there's some more leeway. A whole oscillation being gone surely is suspicious and you want to shut off but that might take another millisecond or two.
Maybe just look at how these inverters work before babbling about. These kits all come with standard off the shelf micro inverters, or rarely bigger string inverters, and will feed back up to 0,8wk into the grid if the energy is not used in the household. If the connection to the grid is lost they turn off within less than 50ms, making them completely safe for line technicians
Even more precisely: If the energy isn't used on the exact phase the inverter is connected to. You might be simultaneously backfeeding 800W on one phase and draw 3000W from the grid for your kettle on another, pretty much every single installation (at least in Germany) is three-phase at the main breaker panel, then distributing (and three-phase for the stove). Good ole Ferraris meters only record the total sum (the wheel would turn at the speed of 2200W) but you're still using grid infrastructure which is one of the reasons why the installations have to be small: Because your utility can't bill you for grid usage.
Do you know how these kits work? The whole point is that they're plug-and-play. If the feed back into the grid, they are not plug and play and will require coordination with your power company lest you accidentally kill someone because you're backfeeding into a line they turned off so they could work on it.
The kits have built-in measures to avoid backfeeding, or they would be illegal. Where I live, they've been deemed so unsafe, failsafe or not, that you're just not allowed to use them.
Why dont they install switches on both ends of the line? Seems obvious. Power is no longer unidirectional.
Decentralized grids are the future.
They cannot back feed when there is no grid power, yes. But they cannot differ between power used inside the house or outside the house. They can and will definitely push power back out to the grid as long as they detect grid power from other sources.
Yes I do. Had one for some time before we got our own house and ramped it up to a "real" 8 kWp array.
Which is exactly why there are harsh regulations about the index of these things in Germany. Before you plug it in, you have to register exactly where you're plugging what in.
https://en.m.wikipedia.org/wiki/Grid-tie_inverter
https://www.inverter.com/what-is-a-grid-tie-inverter
These kits absolutely can push power into the grid, usually with payment for the generation. Just because they may not be allowed where you live doesn't mean they don't exist.
If you happen to have an old Ferraris meter without a ratchet it can even run backwards when you produce more than you consume. And, of course the 800 Watt EU limit is a worst case limit. If you feed in on a dedicated (no other consumers or generators) line with its own fuse and sufficient wire crossection you can feed in up to about 2 kW. Be aware that the fuse will not trigger if you have a near-short while you generate peak or near peak which can cause overheating and is a fire hazard. While none of the above is legal and you will lose house insurance in case some electric-related fire event occurs it is safe technically.